- Particularly small focal point of just 0.4 mm for exquisitely sharp images
- Variable exposure parameters for optimal contrast and the right grey scales at all times
- Extra-long tube for ideal image geometry and reliably distortion-free images
- Speed dial preferences for various applications and simple, intuitive operation
- Flexible installation options (wall or treatment unit)
- Optional full integration into the popular, all-in-one Romexis software (e.g. with automatic transmission of the exposure parameters)
- Option to directly integrate ProXam iS sensors
The KaVo ProXam iX enables intraoral X-rays at the highest level: designed for intuitive operation, precise positioning and a simple imaging process, the unit is a pleasure to use every day.
Thanks to the extremely small focal point and the variable exposure parameters, the 2D image results of this small X-ray unit are more than compelling.
Impressive quality across a wide range of diagnostic applications.
The small focal point (only 0.4 mm) of the ProXam iX offers the best conditions for incredibly sharp images and its variable exposure parameters ensure optimal contrast and suitable greyscale settings at all times.
The extra-long tube creates an accurate image geometry and guarantees a distortion-free display of the image results.
Simple and user-friendly with versatile installation options.
Wherever the KaVo ProXam iX is used – the unit can be attached either directly to the treatment unit or to the wall.
With five different arm lengths and seven different tubes and collimators, the ProXam iX offers a variety of individual setting options and a wide range of uses.
Pre-programmed adult and child modes are available for the numerous areas of application:
- Periapical application
- Occlusal application
- Bitewing or endodontic images
Alternatively, all important exposure value parameters can be set separately:
- 60 – 70 kV
- 2 – 8 mA
- 0.01 – 2 seconds exposure time
As much as necessary, as little as possible – the optimal dose of radiation.
The KaVo ProXam iX works according to the ALADA principle, abbreviated to "As low as diagnostically acceptable". ALADA means that the emitted dose of radiation per X-ray is only as high as absolutely necessary to generate a diagnostically good image.
The required exposure values are automatically retrieved based on the unit's selected setting and the lowest possible radiation dose for the image is calculated. A rectangular tube can also be used to further reduce the radiation dose, which focuses the radiation on a smaller image area.
- Easy and accurate positioning, stable arm, very light weight and compact size
- Very long range (203 cm)
- Hygienic surfaces
- Hand-held remote control or fixed panel, remotely installable
- Small focal spot, automatic compensation for mains voltage fluctuation
- Adjustable anode voltage (60, 63, 66 and 70 kV)
- Adjustable anode current 2, 3, 4, 5, 6, 7, 8 mA
- 24 visually detectable density levels of the exposure times
- 11 levels of density for different films
- Pre-programmable exposure parameters
- Optimised image quality for all techniques, outstanding definition and sharpness
- Short and long tube (200 and 300 mm), density compensation for different tubes
- Right angle tube for better radiation hygiene
- Automatic switch-on control
- Self-diagnostic system and help codes
Assembly:
- Wall mounting (default)
- KaVo treatment unit integration
- 5 selectable extension arms
- Tube head design: near the patient's chest during occlusal imaging
- Each KaVo ProXam iX X-ray unit is prepared for use of the KaVo ProXam iS sensors. The sensors can be attached directly to the X-ray source.
Full digital integration with Romexis.
Full integration into the Romexis software platform is possible. In combination with the ProXam iS sensors and the optionally available connector box, the exposure parameters can be automatically transferred to Romexis and stored in the respective patient file. This eliminates the need to enter the data manually at a later time.
Technical specification
KaVo ProXam iX | |
---|---|
Generator | Direct voltage, microprocessor-controlled, operating frequency 66 kHz |
X-ray tube | Toshiba D-041SB |
Focal spot | 0.4 mm according to IEC 60336 |
Tube diameter | 60 mm, round 36×45 mm, rectangular |
Filtration | min. 2,5 mm Al |
Anode Voltage | 60, 63, 66, 70 kV; ±1 kV adjustable work area |
Rise time | 8 ms at 70 kV |
Anode Current | 2 – 8 mA DC, 1mA steps |
Exposure times | 0.01- 2.0 seconds, 24 stages |
Focus skin distance (standard/ long) | Round (200 mm/ 300 mm) rectangular (300 mm/ 340 mm) |
Mains voltage | 100/110-115/220-240 ±10%, 50/60Hz |
Fusing | 15 AT/ 8 AT |
Duty cycle | 1:30, automatic control |
Weight | 33 kg total x-ray emitter: 4.2 kg with standard tube, 4.5 kg with long tube Range |
Range | 152 cm, 165 cm, 178 cm, 191 cm, 203 cm |
Accessories:
ProXam iX Connector Box
for an automatic transmission of the exposure parameters of KaVo ProXam iX to ROMEXIS
Mat. No.: 2.023.1052
30 cm round tube
Long tube for focused radiation
Mat. No.: 2.023.1053
35 cm rectangular tube
Rectangular tube for focused radiation
Mat. No.: 2.023.1059
Rectangular collimator 30x23mm sensor S0
For ProXam iS sensor size 0
Mat. No.: 2.023.1058
Rectangular collimator 38x25mm sensor S1
For ProXam iS sensor size 1
Mat. No.: 2.023.1057
Rectangular collimator 43 x 31 mm sensor S2
For ProXam iS sensor size 2
Mat. No.: 2.023.1056
Rectangular collimator 43x33 mm scanner
For film
Mat. No.: 2.023.1054
Rectangular collimator 42x23 mm scanner
For film
Mat. No.: 2.023.1055
Wall switch EU
Mat. No.: 2.023.1051
Telephone cable, 12 m
For the remote use of the manual remote control, e.g. outside the x-ray room
Mat. No.: 2.023.1060
Wall socket
for the remote use of the manual remote control, e.g. outside the x-ray room
Mat. No.: 2.023.1061