SONICflex™️ prep

  • Tips diamond-coated on one side having a defined edge angle
  • Preparation (with level 3) and finishing (level 1) of approximal cavities for inlays and partial crowns
  • Prevention of undesired undercutting
  • Precise preparation of various bevel angles, around margins
  • Precise preparation result
  • Reproducible results
  • Improved preparation margins for dental technicians
  • No damage to neighbouring teeth
  • Defined angles

SONICflex prep gold / ceram / CAD/CAM / crown Tips for prosthetics for adhesive inlays and onlays.

The problem

Ideally, approximal adhesive inlays and onlays fit exactly into the cavity: with different bevel angles and edges, harmonious transitions, no undercuts. Practically this is extremely difficult to achieve. Rotating instruments often give rise to the opposite: irregular shapes and edges and hence a poor basis for the dental technician, unnecessarily large extensions.

The solution

KaVo SONICflex prep ceram permits perfect finishing and exactly defined cavities through precise transfer of the geometry of the tips directly to the tooth substance. With tips specially developed for adhesive inlays and onlays.

SONICflex prep = Tips for defined approximal finishing for adhesive inlays and onlays

Features

  • No damage to adjacent teeth
  • Precise transmission of the tip's geometry to the marginal cavity angles
    - no undesired undercutting
    - specific achievement of the bevel angles
    - harmonious transitions between cervical and lateral edge areas
    - marginal areas and preparation surfaces are smooth and free from defects
  • Improve dental restoration by optimisation of cavity form
  • Suitable for all fully ceramic, or finegrain, hybrid composites (e.g. CEREC®*, EMPRESS®**, TARGIS VECTRIS®**, ...)
  • Reproducibility of treatment results
  • Reduction of treatment stress in critical processes
  • Reduction of the "skill-dependency" of complex preparatory work, due to ease of operation
  • Reduction of duration of preparatory work
  • Conservation of healthy tooth tissue

*   Registered trademark of SIRONA Dental Systems GmbH + Co. KG, Bensheim, Germany
** Registered trademark of IVOCLAR AG, Schaan, Liechtenstein

SONICflex prep gold Tips

SONICflex prep gold tip No. 49 mesial

  • Therapy: precise preparation of various bevel-angles around margins, after "rough preparation" with rotary instrument; this enables improved dental restoration
  • Form: mesial, tips with defined bevel-angles: lateral 30-45° and cervical 30°, diamond coating D 46
  • Order number: 0.571.7212
    (compatible with SONICflex 2000 N / L, 2003 / L)
  • Order number: 1.006.1983
    (compatible with SONICflex 2008 / L, 2008 S / LS) 

SONICflex prep gold tip No. 50 distal

  • Therapy: precise preparation of various bevel-angles around margins, after "rough preparation" with rotary instruments; this enables improved dental restoration
  • Form: distal, tips with defined bevel-edges: lateral 30-45° and cervical 30°, diamond coating D 46
  • Order number: 0.571.7222
    (compatible with SONICflex 2000 N / L, 2003 / L)
  • Order number: 1.006.1984
    (compatible with SONICflex 2008 / L, 2008 S / LS) 

SONICflex prep cream Tips

SONICflex prep ceram tip No. 51

  • Treatment: precise preparation of various bevel-angles around margins, with gradual angle transitions from cervical to lateral areas
  • Form: mesial, tips with defined bevel-angles: lateral 60° and cervical 75°, diamond coating D 46 - divergence 2°
  • Order number: 0.571.7262
    (compatible with SONICflex 2000 N / L, 2003 / L)
  • Order number: 1.006.1985
    (compatible with SONICflex 2008 / L, 2008 S / LS) 

SONICflex prep ceram tip No. 52

  • Treatment: precise preparation of various bevel-angles around margins, with gradual angle transitions from cervical to lateral areas
  • Form: distal, tips with defined bevel-edges, lateral 60° and cervical 75°, diamond coating D 46 - divergence 2°
  • Order number: 0.571.7272
    (compatible with SONICflex 2000 N / L, 2003 / L)
  • Order number: 1.006.1986
    (compatible with SONICflex 2008 / L, 2008 S / LS) 

SONICflex prep CAD/CAM Tips

SONICflex prep CAD/CAM tip No. 34

  • Therapy: perfect adaptation of cavity preparations, to the specific requirements of CAD-CAM systems
  • Form: mesial, lateral angle 60° and cervical angle 90°, diamond coating D 46 - divergence 2°
  • Order number: 1.002.1984
    (compatible with SONICflex 2000 N / L, 2003 / L) 
  • Order number: 1.006.1977
    (compatible with SONICflex 2008 / L, 2008 S / LS)

SONICflex prep CAD / CAM tip No. 35

  • Therapy: perfect adaptation of cavity preparations, to the specific requirements of CAD-CAM systems
  • Form: distal, lateral angle 60° and cervical angle 90°, diamond coating D 46 - divergence 2°
  • Order number: 1.002.1986
    (compatible with SONICflex 2000 N / L, 2003 / L) 
  • Order number: 1.006.1979
    (compatible with SONICflex 2008 / L, 2008 S / LS)

SONICflex crown prep Tips

SONICflex crown prep tip No. 97

  • Therapy: crown preparation - the use of rotary, crown preparation instruments, in combination with sonically-vibrated tips of similar form, is the perfect protocol for successful crown preparations.
  • Form: radius, diamond coating D46
  • Order number: 1.008.6383
    (compatible with SONICflex 2000 N / L and 2003 / L) 
  • Order number: 1.008.6384
    (compatible with SONICflex 2008 / L, 2008 S / LS)

SONICflex crown prep tip No. 98

  • Therapy: crown preparation - the use of rotary, crown preparation instruments, in combination with sonically-vibrated tips of similar form, is the perfect protocol for successful crown preparations.
  • Form: radius, diamond coating D46
  • Order number: 1.008.6385
    (compatible with SONICflex 2000 N / L and 2003 / L) 
  • Order number: 1.008.6386
    (compatible with SONICflex 2008 / L, 2008 S)

Inserting SONICflex tips

The working end to be used is screwed onto the SONICflex handpiece with the supplied torque wrench until you feel it snap into place. The working tip is now secured in the handpiece.

If the SONICflex handpiece is to remain on the treatment unit with the tip attached, we recommend leaving the supplied screw-in aid attached so that there is no risk of injury from the working tip.